Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 54
Page 112
Masonry shall conform to the regulations of this Chapter and shall be limited to
the materials specified in this Chapter. ... MASONRY UNIT is any brick, tile, block,
or natural stone conforming to the requirements of Section 2402. (c) Use of ...
Masonry shall conform to the regulations of this Chapter and shall be limited to
the materials specified in this Chapter. ... MASONRY UNIT is any brick, tile, block,
or natural stone conforming to the requirements of Section 2402. (c) Use of ...
Page 113
Hollow concrete block Materials or tile shall conform to the requirements of
A.S.T.M. “Standard (Cont'd.) Specifications for Hollow Load-Bearing Concrete
Masonry Units,” (C90-39). (e) Gypsum and Gypsum Block or Tile. Gypsum shall
conform ...
Hollow concrete block Materials or tile shall conform to the requirements of
A.S.T.M. “Standard (Cont'd.) Specifications for Hollow Load-Bearing Concrete
Masonry Units,” (C90-39). (e) Gypsum and Gypsum Block or Tile. Gypsum shall
conform ...
Page 268
Sand shall be washed sand conforming to A.S.T.M. “Standard Specifications for
Sand for Use in Plaster,” (C35-39); except that when used ... Gypsum plaster
shall conform to A.S. T.M. “Standard Specifications for Gypsum Plasters,” (C28-40
).
Sand shall be washed sand conforming to A.S.T.M. “Standard Specifications for
Sand for Use in Plaster,” (C35-39); except that when used ... Gypsum plaster
shall conform to A.S. T.M. “Standard Specifications for Gypsum Plasters,” (C28-40
).
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone