Page 226
The area of any flue or vent shall be not less than the area of the largest vent connection inlet plus 50 per cent ... No vent connection connected to any gas appliance having pilot provision for automatic or remote control , shall be ...
The area of any flue or vent shall be not less than the area of the largest vent connection inlet plus 50 per cent ... No vent connection connected to any gas appliance having pilot provision for automatic or remote control , shall be ...
Page 236
on the street front of the building and such connection shall have two inlets for buildings five stories or less in height ... All interior wet standpipes shall be connected to a street water main of not less than four inches ( 4 " ) in ...
on the street front of the building and such connection shall have two inlets for buildings five stories or less in height ... All interior wet standpipes shall be connected to a street water main of not less than four inches ( 4 " ) in ...
Page 285
Each such inter - connecting member shall be capable of transmitting by both tension and compression at least 10 per cent of the total vertical load carried by the heavier only of the footings or foundations connected .
Each such inter - connecting member shall be capable of transmitting by both tension and compression at least 10 per cent of the total vertical load carried by the heavier only of the footings or foundations connected .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone