Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 36
Page 195
... connecting them to the segments of the member and they shall be connected to each segment by at least three rivets . ( c ) Spacing of Lacing Bars . Lacing bars of compression members shall be so spaced that the ratio / r of the flange ...
... connecting them to the segments of the member and they shall be connected to each segment by at least three rivets . ( c ) Spacing of Lacing Bars . Lacing bars of compression members shall be so spaced that the ratio / r of the flange ...
Page 226
... connection connected to any gas appliance having pilot provision for automatic or remote control , shall be con- nected to any chimney flue which is used as a smoke flue for any stove , boiler , heater or other apparatus designed to ...
... connection connected to any gas appliance having pilot provision for automatic or remote control , shall be con- nected to any chimney flue which is used as a smoke flue for any stove , boiler , heater or other apparatus designed to ...
Page 285
... connected in two direc- tions approximately at right angles to each other . Each such inter - connecting member shall be capable of transmitting by both tension and compression at least 10 per cent of the total vertical load carried by ...
... connected in two direc- tions approximately at right angles to each other . Each such inter - connecting member shall be capable of transmitting by both tension and compression at least 10 per cent of the total vertical load carried by ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood