Page 226
... connection inlet plus 50 per cent of the areas of all other additional inlets , provided that no gas flue or vent shall have an area of less than twelve square inches ( 12 sq . in . ) , and shall be not less than two inches ( 2 ′′ ) in ...
... connection inlet plus 50 per cent of the areas of all other additional inlets , provided that no gas flue or vent shall have an area of less than twelve square inches ( 12 sq . in . ) , and shall be not less than two inches ( 2 ′′ ) in ...
Page 234
... connections shall be of sufficient strength to withstand 300 pounds of water pressure to the square inch when ready for ... connection . All Siamese inlet connec- tions shall be located on a street front of the building and not less than ...
... connections shall be of sufficient strength to withstand 300 pounds of water pressure to the square inch when ready for ... connection . All Siamese inlet connec- tions shall be located on a street front of the building and not less than ...
Page 235
... connections and such sign shall read : " CONNECTION TO DRY STANDPIPE . " Sec . 3805. Every Group A , B and C occupancy of any height Wet and every Group D , E , F , G and H occupancy three or more Standpipes ; stories in height and ...
... connections and such sign shall read : " CONNECTION TO DRY STANDPIPE . " Sec . 3805. Every Group A , B and C occupancy of any height Wet and every Group D , E , F , G and H occupancy three or more Standpipes ; stories in height and ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood