Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 80
Page 85
... constructed , moved within or into Fire Zone No. 2 and such buildings over one thousand square feet ( 1,000 sq . ft . ) in area , erected , constructed , moved within or into Fire Zone No. 2 shall have all exterior walls of not less ...
... constructed , moved within or into Fire Zone No. 2 and such buildings over one thousand square feet ( 1,000 sq . ft . ) in area , erected , constructed , moved within or into Fire Zone No. 2 shall have all exterior walls of not less ...
Page 91
... constructed as to transfer horizontal forces to such parts of the structural frame as are designed to carry the horizontal forces to the foundations , unless such forces are provided for otherwise . Where wood sleepers are used for ...
... constructed as to transfer horizontal forces to such parts of the structural frame as are designed to carry the horizontal forces to the foundations , unless such forces are provided for otherwise . Where wood sleepers are used for ...
Page 231
... constructed Burners and erected as required for similar apparatus using solid fuel . Oil burning apparatus using commercial fuel oil , furnace oil , diesel oil or other flammable liquids shall be constructed and installed in compliance ...
... constructed Burners and erected as required for similar apparatus using solid fuel . Oil burning apparatus using commercial fuel oil , furnace oil , diesel oil or other flammable liquids shall be constructed and installed in compliance ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood