Page 87
... CONSTRUCTION AND GENERAL REQUIREMENTS Sec . 1701. The requirements of Part V are the minimum re- General quirements for the various Types of Construction . In order that a building may be classed in any specific Type of Construction ...
... CONSTRUCTION AND GENERAL REQUIREMENTS Sec . 1701. The requirements of Part V are the minimum re- General quirements for the various Types of Construction . In order that a building may be classed in any specific Type of Construction ...
Page 95
... construction shall be protected by a suspended ceiling of not less than two - hour fire - resistive construction , and such ceiling shall be not less than six inches ( 6 " ) distant from any part of such roof construc- tion . ( b ) Wood ...
... construction shall be protected by a suspended ceiling of not less than two - hour fire - resistive construction , and such ceiling shall be not less than six inches ( 6 " ) distant from any part of such roof construc- tion . ( b ) Wood ...
Page 254
... construction shall consist of reinforced concrete , gypsum or solid ma- sonry slabs or arches not less than four ... construction , all reinforcing , tie rods and supporting structural members in such floors shall be protected with not ...
... construction shall consist of reinforced concrete , gypsum or solid ma- sonry slabs or arches not less than four ... construction , all reinforcing , tie rods and supporting structural members in such floors shall be protected with not ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood