Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 15
Page 58
... corridor , plus one - half the sum of the widths of all other doors opening into the corridor . There shall be no openings in such corridors other than the exit openings , and the exit doors shall be hung so as not to decrease the ...
... corridor , plus one - half the sum of the widths of all other doors opening into the corridor . There shall be no openings in such corridors other than the exit openings , and the exit doors shall be hung so as not to decrease the ...
Page 66
... corridors , halls or stairs . 10. Where Class 1 rooms other than those designed to be used simultaneously with other rooms exit into a corridor or hall that serves as a required means of egress from other rooms , the corridor , hall ...
... corridors , halls or stairs . 10. Where Class 1 rooms other than those designed to be used simultaneously with other rooms exit into a corridor or hall that serves as a required means of egress from other rooms , the corridor , hall ...
Page 67
... corridors , halls or stairs . 14. There shall be no dead end in any corridor or hall more than ten feet ( 10 ' ) beyond the exit stair or door . 15. Any room , the floor of which is below ground and which is used by pupils shall have at ...
... corridors , halls or stairs . 14. There shall be no dead end in any corridor or hall more than ten feet ( 10 ' ) beyond the exit stair or door . 15. Any room , the floor of which is below ground and which is used by pupils shall have at ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood