Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 35
Page 154
... direction in which moments are considered ( see Section 2619 ) . Span length of flat slab panel center to center of col- umns , perpendicular to the rectangular direction in which moments are considered . = Clear span for positive ...
... direction in which moments are considered ( see Section 2619 ) . Span length of flat slab panel center to center of col- umns , perpendicular to the rectangular direction in which moments are considered . = Clear span for positive ...
Page 160
... direction only . Such reinforcement shall provide for the following minimum ratios of reinforcement area to con- crete area ( bd ) , but in no case shall such reinforcing bars be placed farther apart than five times the slab thickness ...
... direction only . Such reinforcement shall provide for the following minimum ratios of reinforcement area to con- crete area ( bd ) , but in no case shall such reinforcing bars be placed farther apart than five times the slab thickness ...
Page 285
... direction horizontally Normal to surface of wall Normal to surface of wall Any direction horizontally tanks plus contents , chim- neys , smokestacks , and penthouses when connected to or a part of a building .05 Any direction ...
... direction horizontally Normal to surface of wall Normal to surface of wall Any direction horizontally tanks plus contents , chim- neys , smokestacks , and penthouses when connected to or a part of a building .05 Any direction ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood