Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 67
Page 59
... Doors and Gates . All exit and entrance doors or gates shall swing in the direction of exit travel and if provided with latches such latches shall be of self - releasing type , such as panic bolts or similar devices , which will permit the ...
... Doors and Gates . All exit and entrance doors or gates shall swing in the direction of exit travel and if provided with latches such latches shall be of self - releasing type , such as panic bolts or similar devices , which will permit the ...
Page 215
... doors providing egress from public hallways and all doors providing egress from the building shall open in the direction of exit travel , except sliding doors as provided in Section 3304 . Sec . 3304. Doors shall not open immediately on ...
... doors providing egress from public hallways and all doors providing egress from the building shall open in the direction of exit travel , except sliding doors as provided in Section 3304 . Sec . 3304. Doors shall not open immediately on ...
Page 257
... doors bearing the label of the Underwriters ' Labora- tories , Incorporated , shall be accepted as meeting the require- ments of any of the above doors . Hardware for sheet metal and tin - clad fire doors referred to in paragraphs No. 1 ...
... doors bearing the label of the Underwriters ' Labora- tories , Incorporated , shall be accepted as meeting the require- ments of any of the above doors . Hardware for sheet metal and tin - clad fire doors referred to in paragraphs No. 1 ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood