Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 53
Page 94
... Enclosures for elevator shafts , vent shafts , stair wells and other vertical openings shall be of not less than two- hour fire - resistive construction , ( see Chapter 30 ) ; provided , that in buildings not more than three stories in ...
... Enclosures for elevator shafts , vent shafts , stair wells and other vertical openings shall be of not less than two- hour fire - resistive construction , ( see Chapter 30 ) ; provided , that in buildings not more than three stories in ...
Page 208
Pacific Coast Building Officials Conference. Enclosures : When Required Stairway , Ramp , and Elevator Enclosures Other Vertical Openings CHAPTER 30 - ENCLOSURE OF VERTICAL OPENINGS Sec . 3001. Vertical openings are required to be ...
Pacific Coast Building Officials Conference. Enclosures : When Required Stairway , Ramp , and Elevator Enclosures Other Vertical Openings CHAPTER 30 - ENCLOSURE OF VERTICAL OPENINGS Sec . 3001. Vertical openings are required to be ...
Page 217
... enclosure requirements . Exit enclosures shall not be used for storage in any manner whatsoever and shall not contain any material or equipment liable to cause fire , explosion or panic . At the top of every stairway enclosure a ...
... enclosure requirements . Exit enclosures shall not be used for storage in any manner whatsoever and shall not contain any material or equipment liable to cause fire , explosion or panic . At the top of every stairway enclosure a ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood