Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 34
Page 33
... erected , constructed , en- larged , altered , repaired , moved , converted to other uses or de- molished and to regulate the equipment , maintenance , use and occupancy of all buildings and structures . The provisions of this Code ...
... erected , constructed , en- larged , altered , repaired , moved , converted to other uses or de- molished and to regulate the equipment , maintenance , use and occupancy of all buildings and structures . The provisions of this Code ...
Page 84
... erected in Fire Zones Nos . 1 or 2 by special permit from the Building Inspector for a limited period of time , and such building or structure shall be com- pletely removed upon the expiration of the time limit stated in such permit ...
... erected in Fire Zones Nos . 1 or 2 by special permit from the Building Inspector for a limited period of time , and such building or structure shall be com- pletely removed upon the expiration of the time limit stated in such permit ...
Page 85
... erected in Fire Zone No. 1 . No building of Type IV construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered ...
... erected in Fire Zone No. 1 . No building of Type IV construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood