Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 83
Page 93
... exceed a height of Height seventy - five feet ( 75 ' ) ; provided , that the height of a building Allowable erected on sloping ground may be not to exceed seventy - five feet ( 75 ' ) plus a vertical distance equal to the vertical ...
... exceed a height of Height seventy - five feet ( 75 ' ) ; provided , that the height of a building Allowable erected on sloping ground may be not to exceed seventy - five feet ( 75 ' ) plus a vertical distance equal to the vertical ...
Page 103
... exceed forty - five feet ( 45 ′ ) above the adjacent fin- ished ground level ; provided , further , that spires , towers or steeples erected as a part of such building and not used for habitation or storage may extend not to exceed ten ...
... exceed forty - five feet ( 45 ′ ) above the adjacent fin- ished ground level ; provided , further , that spires , towers or steeples erected as a part of such building and not used for habitation or storage may extend not to exceed ten ...
Page 197
... exceed 180 . Steel Construction The effective width of flanges on such members having a channel section shall not exceed 20 times the thickness of the ( Cont'd . ) flange . The effective width of flanges on such members having an I ...
... exceed 180 . Steel Construction The effective width of flanges on such members having a channel section shall not exceed 20 times the thickness of the ( Cont'd . ) flange . The effective width of flanges on such members having an I ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood