Page 223
Towers not enclosed and which extend more than Spires seventy-five feet (75')
above grade shall have their framework constructed of iron, steel or reinforced
concrete. No tower or spire shall occupy more than one-fourth of the street
frontage ...
Towers not enclosed and which extend more than Spires seventy-five feet (75')
above grade shall have their framework constructed of iron, steel or reinforced
concrete. No tower or spire shall occupy more than one-fourth of the street
frontage ...
Page 226
Every vent shall extend in as nearly a vertical position as possible and be
continuous from the gas appliance to the outside of the building and extend at
least two feet (2') above any portion of the roof within fifteen feet (15') of said vent.
No vent ...
Every vent shall extend in as nearly a vertical position as possible and be
continuous from the gas appliance to the outside of the building and extend at
least two feet (2') above any portion of the roof within fifteen feet (15') of said vent.
No vent ...
Page 289
Wood posts or columns shall not extend through or be placed directly on
concrete floors. They shall be supported on concrete footings extending at least
two inches (2") above the finished floor or may be placed on a corrosion-resisting
metal ...
Wood posts or columns shall not extend through or be placed directly on
concrete floors. They shall be supported on concrete footings extending at least
two inches (2") above the finished floor or may be placed on a corrosion-resisting
metal ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone