... extend more than twelve feet ( 12 ′ ) in height above the roof . The aggregate area of all penthouses and other roof structures shall not exceed 20 per cent of the area of the roof . No penthouse , bulkhead or any other similar ...
... extend more than twelve feet ( 12 ′ ) in height above the roof . The aggregate area of all penthouses and other roof structures shall not exceed 20 per cent of the area of the roof . No penthouse , bulkhead or any other similar ...
Page 226
... extend in as nearly a vertical position as possible and be continuous from the gas appliance to the out- side of the building and extend at least two feet ( 2 ′ ) above any portion of the roof within fifteen feet ( 15 ' ) of said vent ...
... extend in as nearly a vertical position as possible and be continuous from the gas appliance to the out- side of the building and extend at least two feet ( 2 ′ ) above any portion of the roof within fifteen feet ( 15 ' ) of said vent ...
Page 289
... extend through or be placed directly on concrete floors . They shall be supported on concrete footings extending at least two inches ( 2 " ) above the finished floor or may be placed on a corrosion - resisting metal plate at least one ...
... extend through or be placed directly on concrete floors . They shall be supported on concrete footings extending at least two inches ( 2 " ) above the finished floor or may be placed on a corrosion - resisting metal plate at least one ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood