Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 84
Page 93
... Exterior walls shall be of not less than four- Exterior hour fire - resistive construction , except that walls fronting on and Inner streets having a width of at least fifty feet ( 50 ' ) in Fire Court Walls Zone No. 1 or thirty feet ...
... Exterior walls shall be of not less than four- Exterior hour fire - resistive construction , except that walls fronting on and Inner streets having a width of at least fifty feet ( 50 ' ) in Fire Court Walls Zone No. 1 or thirty feet ...
Page 105
... exterior walls covered with a solid sheathing as set forth in this section . Exterior Walls and Wall Coverings ( Cont'd . ) ( c ) Wall Coverings . 1. General . Exterior walls shall be Wall Coverings covered on the outside with the ...
... exterior walls covered with a solid sheathing as set forth in this section . Exterior Walls and Wall Coverings ( Cont'd . ) ( c ) Wall Coverings . 1. General . Exterior walls shall be Wall Coverings covered on the outside with the ...
Page 281
... Exterior Plaster . ( 1 ) Exterior Lathing . Studs shall be sheathed , or wire of not less than 18 Plaster W & M gauge shall be stretched taut horizontally at intervals not exceeding six inches ( 6 " ) on centers vertically and securely ...
... Exterior Plaster . ( 1 ) Exterior Lathing . Studs shall be sheathed , or wire of not less than 18 Plaster W & M gauge shall be stretched taut horizontally at intervals not exceeding six inches ( 6 " ) on centers vertically and securely ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood