Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 65
Page 98
... Exterior walls shall be of fire - resistive materials . Partitions , floors and roof framing may be of wood . Sec . 2002. Type III buildings shall not exceed a height of fifty - five feet ( 55 ' ) ; provided , that the height of a ...
... Exterior walls shall be of fire - resistive materials . Partitions , floors and roof framing may be of wood . Sec . 2002. Type III buildings shall not exceed a height of fifty - five feet ( 55 ' ) ; provided , that the height of a ...
Page 104
Pacific Coast Building Officials Conference. Retaining Walls Exterior Walls and Foundation walls and all other walls used as retaining walls in connection with Type V buildings shall be not less than eight inches ( 8 " ) in thickness ...
Pacific Coast Building Officials Conference. Retaining Walls Exterior Walls and Foundation walls and all other walls used as retaining walls in connection with Type V buildings shall be not less than eight inches ( 8 " ) in thickness ...
Page 105
... exterior walls covered with a solid sheathing as set forth in this section . Exterior Walls and Wall Coverings ( Cont'd . ) ( c ) Wall Coverings . 1. General . Exterior walls shall be Wall Coverings covered on the outside with the ...
... exterior walls covered with a solid sheathing as set forth in this section . Exterior Walls and Wall Coverings ( Cont'd . ) ( c ) Wall Coverings . 1. General . Exterior walls shall be Wall Coverings covered on the outside with the ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood