Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 33
Page 5
... face of wall , thus giving greater beam depth . 7 4 MATT FACE . Gives Textured finish for outside walls , also provides bond for damp - proof- ing , plastering , and brush coat finishes . DAVIDSON SPECIAL UNITS . Are the only brick ...
... face of wall , thus giving greater beam depth . 7 4 MATT FACE . Gives Textured finish for outside walls , also provides bond for damp - proof- ing , plastering , and brush coat finishes . DAVIDSON SPECIAL UNITS . Are the only brick ...
Page 183
... face of the column or pedestal supported by the footing . In footings on piles the critical section shall be assumed at a d distance from the face of the column or pedestal , and any — 2 piles whose centers are at or within the section ...
... face of the column or pedestal supported by the footing . In footings on piles the critical section shall be assumed at a d distance from the face of the column or pedestal , and any — 2 piles whose centers are at or within the section ...
Page 253
... face Shells 12 - in . face Shells Unplastered 8 Plastered one side 82 4t 412t Unplastered 12 ** 8 Plastered each side 9 24 - in . face Shells Unplastered 8 13 % -in . face Shells Unplastered 8 4+ Plastered each side 9 5+ Other ...
... face Shells 12 - in . face Shells Unplastered 8 Plastered one side 82 4t 412t Unplastered 12 ** 8 Plastered each side 9 24 - in . face Shells Unplastered 8 13 % -in . face Shells Unplastered 8 4+ Plastered each side 9 5+ Other ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood