Page 48
... above , except that the topmost story shall be that portion of a building included between the upper surface of the ... feet ( 6 ' ) above grade such basement or cellar shall be considered a story . STREET is any thoroughfare or public park ...
... above , except that the topmost story shall be that portion of a building included between the upper surface of the ... feet ( 6 ' ) above grade such basement or cellar shall be considered a story . STREET is any thoroughfare or public park ...
Page 223
... feet ( 28 ' ) in height above the roof and Roof when used as an enclosure ... grade shall have their framework constructed of iron , steel or reinforced ... feet ( 1,600 sq . ft . ) unless it conforms entirely to the type of construction ...
... feet ( 28 ' ) in height above the roof and Roof when used as an enclosure ... grade shall have their framework constructed of iron , steel or reinforced ... feet ( 1,600 sq . ft . ) unless it conforms entirely to the type of construction ...
Page 264
... feet or less DISTANCE FROM CONSTRUCTION TO WALKWAY Less than six feet More ... above grade , placed on the side of the walkway nearest to the building site ... feet ( 10 ' ) above the walkway . The roof shall be tightly boarded . Every ...
... feet or less DISTANCE FROM CONSTRUCTION TO WALKWAY Less than six feet More ... above grade , placed on the side of the walkway nearest to the building site ... feet ( 10 ' ) above the walkway . The roof shall be tightly boarded . Every ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood