... Finish Coats for Gypsum or Lime Plaster . The finish coats shall be mixed and proportioned in accordance with the following procedure : 1. Smooth white finish , mixed in the proportion of not less than one part gypsum gauging plaster or ...
... Finish Coats for Gypsum or Lime Plaster . The finish coats shall be mixed and proportioned in accordance with the following procedure : 1. Smooth white finish , mixed in the proportion of not less than one part gypsum gauging plaster or ...
Page 273
... finish , mixed in the proportions of three parts Keene's cement to one part lime putty , by volume . 5. Lime sand - float finish shall be mixed in the proportion of one part gypsum gauging plaster or Keene's cement , three parts of lime ...
... finish , mixed in the proportions of three parts Keene's cement to one part lime putty , by volume . 5. Lime sand - float finish shall be mixed in the proportion of one part gypsum gauging plaster or Keene's cement , three parts of lime ...
Page 281
... finish 2 ** 1/8 " * Measured from backing to crest of scored plaster . ** Approved prepared finish coats containing not less than 1/3 by weight of port- land cement may be used . Exterior Plaster Plasticity agents shall be of approved ...
... finish 2 ** 1/8 " * Measured from backing to crest of scored plaster . ** Approved prepared finish coats containing not less than 1/3 by weight of port- land cement may be used . Exterior Plaster Plasticity agents shall be of approved ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood