... FIRE DOORS WHITE METAL , BRONZE AND COPPER DOORS ELEVATOR DOORS AND WAREHOUSE DOORS FIRE DOOR HARDWARE ' ACME ' " SECO " STORE FRONT MOULDINGS MIRROR AND SIGN FRAME MOULDINGS CHROME METAL COVERED MOULDINGS Agents for COUNTER BALANCED ...
... FIRE DOORS WHITE METAL , BRONZE AND COPPER DOORS ELEVATOR DOORS AND WAREHOUSE DOORS FIRE DOOR HARDWARE ' ACME ' " SECO " STORE FRONT MOULDINGS MIRROR AND SIGN FRAME MOULDINGS CHROME METAL COVERED MOULDINGS Agents for COUNTER BALANCED ...
Page 257
... Fire doors bearing the label of the Underwriters ' Labora- tories , Incorporated , shall be accepted as meeting the require- ments of any of the above doors . Hardware for sheet metal and tin - clad fire doors referred to in paragraphs ...
... Fire doors bearing the label of the Underwriters ' Labora- tories , Incorporated , shall be accepted as meeting the require- ments of any of the above doors . Hardware for sheet metal and tin - clad fire doors referred to in paragraphs ...
Page 258
... Fire Underwriters , recommended by the National Fire Protection Association , Edition of January , 1939.1 All fire doors shall be so hung that when closed they will fit tightly into place against the wall or frame so as to prove an ...
... Fire Underwriters , recommended by the National Fire Protection Association , Edition of January , 1939.1 All fire doors shall be so hung that when closed they will fit tightly into place against the wall or frame so as to prove an ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood