Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 83
Page 104
... four hundred square feet ( 400 Wall Coverings sq . ft . ) or more , including additions , shall be constructed with studding not less than two inches by four inches ( 2 " x4 " ) spaced not more than sixteen inches ( 16 " ) on centers ...
... four hundred square feet ( 400 Wall Coverings sq . ft . ) or more , including additions , shall be constructed with studding not less than two inches by four inches ( 2 " x4 " ) spaced not more than sixteen inches ( 16 " ) on centers ...
Page 140
... four - inch ( 2 " x4 " ) studs ; for buildings of three stories , the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ′′ x6 ′′ ) to the bottom of the second floor joists and two ...
... four - inch ( 2 " x4 " ) studs ; for buildings of three stories , the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ′′ x6 ′′ ) to the bottom of the second floor joists and two ...
Page 153
... four sides ) . Ratio as defined above , but applying to Span B ( floors with supports on four sides ) . The distances , assumed for purposes of load distribution , between inflection points in spans A and B respectively ( floors with ...
... four sides ) . Ratio as defined above , but applying to Span B ( floors with supports on four sides ) . The distances , assumed for purposes of load distribution , between inflection points in spans A and B respectively ( floors with ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood