Page 90
... frame the floor and roof panel construction shall be designed and constructed to carry the horizontal forces to such parts of the structural frame as are designed to carry the horizontal forces to the foundations . The entire structural ...
... frame the floor and roof panel construction shall be designed and constructed to carry the horizontal forces to such parts of the structural frame as are designed to carry the horizontal forces to the foundations . The entire structural ...
Page 94
... frame shall be directly superimposed , one above the other , ( no girders or bolsters be- tween columns ) and shall ... frames and structural members for elevators and elevator enclosures ) shall be thor- oughly fire - protected . Such ...
... frame shall be directly superimposed , one above the other , ( no girders or bolsters be- tween columns ) and shall ... frames and structural members for elevators and elevator enclosures ) shall be thor- oughly fire - protected . Such ...
Page 101
... Frame ) Sec . 2101. In " Type IV Buildings " the structural framework Definition shall be of steel , iron , masonry ... frame as to resist effectively wind and other forces that may be applied to it . Wall coverings may be considered a ...
... Frame ) Sec . 2101. In " Type IV Buildings " the structural framework Definition shall be of steel , iron , masonry ... frame as to resist effectively wind and other forces that may be applied to it . Wall coverings may be considered a ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood