Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 37
Page 1
REDWOOD QUALITY IS BASED ON RIGID CRA INSPECTION STANDARDS * You can depend on the grade mark . * CRA ) FOUNDATION MILL MARK REDWOOD Foundation grade Redwood is the special - use grade selected for durability . You'll recognize also the ...
REDWOOD QUALITY IS BASED ON RIGID CRA INSPECTION STANDARDS * You can depend on the grade mark . * CRA ) FOUNDATION MILL MARK REDWOOD Foundation grade Redwood is the special - use grade selected for durability . You'll recognize also the ...
Page 45
BASEMENT is that portion of a building between floor and Definitions ceiling , which is partly below and partly above grade ( as defined ( Cont'd . ) in this Section ) , but so located that the vertical distance from grade to the floor ...
BASEMENT is that portion of a building between floor and Definitions ceiling , which is partly below and partly above grade ( as defined ( Cont'd . ) in this Section ) , but so located that the vertical distance from grade to the floor ...
Page 250
Grade A concrete 2 2 142 1 Grade B concrete 3 212 2 142 Gunite 2 112 1 84 Steel or Cast Iron Col - Brick of clay , shale , con394 244 144 umns ; Projecting Steel crete or sand - line Beam or Girder Clay tile , clay tile and Flanges ...
Grade A concrete 2 2 142 1 Grade B concrete 3 212 2 142 Gunite 2 112 1 84 Steel or Cast Iron Col - Brick of clay , shale , con394 244 144 umns ; Projecting Steel crete or sand - line Beam or Girder Clay tile , clay tile and Flanges ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone