Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 36
Page 45
BASEMENT is that portion of a building between floor and Definitions ceiling,
which is partly below and partly above grade (as defined in this Section), but so
located that the vertical distance from grade to the floor below is less than the
vertical ...
BASEMENT is that portion of a building between floor and Definitions ceiling,
which is partly below and partly above grade (as defined in this Section), but so
located that the vertical distance from grade to the floor below is less than the
vertical ...
Page 112
Except for size all brick of burned clay or shale shall conform to the requirements
for Grade “NW” or Grade “MW” brick given in A.S. T.M. “Tentative Specifications
for Building Brick,” (C62-41T). (b) Concrete Brick. Except for size, concrete brick ...
Except for size all brick of burned clay or shale shall conform to the requirements
for Grade “NW” or Grade “MW” brick given in A.S. T.M. “Tentative Specifications
for Building Brick,” (C62-41T). (b) Concrete Brick. Except for size, concrete brick ...
Page 250
Grade A concrete 2 2 1%. 1 Grade B concrete 3 2%. 2 1% Gunite 2 1%. 1 % Brick
of clay, shale, conSteel or Cast Iron Col- - - 3%. 3%. 234 134 ūs; Projecting
steelcrete or sand-line o, o, o, %. B_e a m or, Gir d e rClay tile, clay tile and
Flanges; ...
Grade A concrete 2 2 1%. 1 Grade B concrete 3 2%. 2 1% Gunite 2 1%. 1 % Brick
of clay, shale, conSteel or Cast Iron Col- - - 3%. 3%. 234 134 ūs; Projecting
steelcrete or sand-line o, o, o, %. B_e a m or, Gir d e rClay tile, clay tile and
Flanges; ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone