Page 46
... ( Ground Level ) is the average of the finished ground level at the center of all walls of a building . In case walls are parallel to and within five feet ( 5 ′ ) of a sidewalk , the above ground level shall be measured at the sidewalk ...
... ( Ground Level ) is the average of the finished ground level at the center of all walls of a building . In case walls are parallel to and within five feet ( 5 ′ ) of a sidewalk , the above ground level shall be measured at the sidewalk ...
Page 103
... ground may be thirty - eight feet ( 38 ' ) plus a vertical distance equal to the vertical change in slope along and in the length of any side of such building but in no case shall such height exceed forty - five feet ( 45 ′ ) above the ...
... ground may be thirty - eight feet ( 38 ' ) plus a vertical distance equal to the vertical change in slope along and in the length of any side of such building but in no case shall such height exceed forty - five feet ( 45 ′ ) above the ...
Page 289
... ground or less than eighteen inches ( 18 ′′ ) above the ground , shall be removed before a building is occupied or used for any purpose . 14. Loose or casual wood shall not be stored in direct con- tact with the ground under any ...
... ground or less than eighteen inches ( 18 ′′ ) above the ground , shall be removed before a building is occupied or used for any purpose . 14. Loose or casual wood shall not be stored in direct con- tact with the ground under any ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood