... hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less than three - hour fire - resistive construction . All openings in walls forming such separation shall be protected on each side thereof by ...
... hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less than three - hour fire - resistive construction . All openings in walls forming such separation shall be protected on each side thereof by ...
Page 247
... hour , three - hour , two - hour or one - hour fire - resistive construction shall meet the respective requirements for such rating as specified in the A.S.T.M. " Stand- ard Specifications for Fire Tests of Building Construction and ...
... hour , three - hour , two - hour or one - hour fire - resistive construction shall meet the respective requirements for such rating as specified in the A.S.T.M. " Stand- ard Specifications for Fire Tests of Building Construction and ...
Page 254
... hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of ...
... hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood