Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 77
Page 230
... inches ( 12 " ) above any wood floors by metal supports and there shall be a metal and asbestos pad at least three - eighths inch ( % " ) thick below such stove extending at least six inches ( 6 ′′ ) beyond each side and at least twelve ...
... inches ( 12 " ) above any wood floors by metal supports and there shall be a metal and asbestos pad at least three - eighths inch ( % " ) thick below such stove extending at least six inches ( 6 ′′ ) beyond each side and at least twelve ...
Page 244
... inches deep . A two - inch pipe batten shall be placed at the top and a one and one - half inch ( 11⁄2 " ) bat- ten at the bottom . For stage openings over forty feet ( 40 ' ) in width the bottom batten shall be not less than two and ...
... inches deep . A two - inch pipe batten shall be placed at the top and a one and one - half inch ( 11⁄2 " ) bat- ten at the bottom . For stage openings over forty feet ( 40 ' ) in width the bottom batten shall be not less than two and ...
Page 257
... inches ( 48 " ) in width . Grooves not less than three - fourths inch Windows ( 4 " ) in depth and three - eighths ... inches by three- eighths inch ( 21⁄2 " x % " ) , and latch bars shall be not less than one and one - half inches by ...
... inches ( 48 " ) in width . Grooves not less than three - fourths inch Windows ( 4 " ) in depth and three - eighths ... inches by three- eighths inch ( 21⁄2 " x % " ) , and latch bars shall be not less than one and one - half inches by ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood