Such stoves shall be securely supported at least twelve inches ( 12 " ) above any wood floors by metal supports and ... and asbestos pad at least three - eighths inch ( 38 " ) thick below such stove extending at least six inches ( 6 ...
Such stoves shall be securely supported at least twelve inches ( 12 " ) above any wood floors by metal supports and ... and asbestos pad at least three - eighths inch ( 38 " ) thick below such stove extending at least six inches ( 6 ...
Page 244
inches ( 8 " ) and shall overlap the top and sides of the proscenium opening at least twelve inches ( 12 " ) . Six - inch ( 6 " ) pockets shall be sewed in the top and the bottom of the curtain to hold the pipe battens ; the sides shall ...
inches ( 8 " ) and shall overlap the top and sides of the proscenium opening at least twelve inches ( 12 " ) . Six - inch ( 6 " ) pockets shall be sewed in the top and the bottom of the curtain to hold the pipe battens ; the sides shall ...
Page 257
than seven hundred and twenty square inches ( 720 sq . in . ) in Fire Doors , area , nor exceed fifty - four inches ( 54 " ) in height or forty - eight Shutters , and inches ( 48 " ) in width . Grooves not less than three - fourths inch ...
than seven hundred and twenty square inches ( 720 sq . in . ) in Fire Doors , area , nor exceed fifty - four inches ( 54 " ) in height or forty - eight Shutters , and inches ( 48 " ) in width . Grooves not less than three - fourths inch ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone