Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 37
Page 93
... incombustible materials . Floors and non - bearing partitions shall be of wood or incombustible materials . Sec . 1902. Type II buildings shall not exceed a height of Height seventy - five feet ( 75 ' ) ; provided , that the height of a ...
... incombustible materials . Floors and non - bearing partitions shall be of wood or incombustible materials . Sec . 1902. Type II buildings shall not exceed a height of Height seventy - five feet ( 75 ' ) ; provided , that the height of a ...
Page 101
... incombustible materials . Partitions , floors and roof construction shall be of incombustible materials except as specified in this Chapter . Foundations shall be of masonry or reinforced concrete . Sec . 2102. Type IV buildings shall ...
... incombustible materials . Partitions , floors and roof construction shall be of incombustible materials except as specified in this Chapter . Foundations shall be of masonry or reinforced concrete . Sec . 2102. Type IV buildings shall ...
Page 253
... Incombustible studding with metal or wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Reinforcement not less than 0.2 % in each direction Unplastered Plastered each side or 6 4 * 3 * 2 * 6 * 5 ...
... Incombustible studding with metal or wire lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Reinforcement not less than 0.2 % in each direction Unplastered Plastered each side or 6 4 * 3 * 2 * 6 * 5 ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood