Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 51
Page 99
... iron , rein- Structural forced concrete , masonry or wood and shall be designed and Framework erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 ...
... iron , rein- Structural forced concrete , masonry or wood and shall be designed and Framework erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 ...
Page 185
... iron used in buildings or structures shall be of such quality as to conform to the A.S.T.M. " Standard Specifications for Gray Iron Castings , " ( A48-41 ) . All structural steel , cast steel and cast iron shall be tested in accordance ...
... iron used in buildings or structures shall be of such quality as to conform to the A.S.T.M. " Standard Specifications for Gray Iron Castings , " ( A48-41 ) . All structural steel , cast steel and cast iron shall be tested in accordance ...
Page 227
... iron bracket at- tached to the studs or framework of the building with through- bolts . When erected on the inside of a building such patent chimneys shall be provided with a smokeproof clean - out of ap- proved design at or near the ...
... iron bracket at- tached to the studs or framework of the building with through- bolts . When erected on the inside of a building such patent chimneys shall be provided with a smokeproof clean - out of ap- proved design at or near the ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood