Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 49
Page 8
... JOINTS - The method of slip joint construction is a simple , easy way of assem- bling and installation that affords α saving in both time and labor . All joints fit perfectly and tie in with each other accurately . 3. CEMENT SEAL - The ...
... JOINTS - The method of slip joint construction is a simple , easy way of assem- bling and installation that affords α saving in both time and labor . All joints fit perfectly and tie in with each other accurately . 3. CEMENT SEAL - The ...
Page 133
... Joints bolt values shall be derived in accordance with the principles ( Cont'd . ) stated in " Wood Handbook , " U. S. Department of Agriculture , September , 1935 . ( e ) Joints Other than Double Shear . When a joint consists of two ...
... Joints bolt values shall be derived in accordance with the principles ( Cont'd . ) stated in " Wood Handbook , " U. S. Department of Agriculture , September , 1935 . ( e ) Joints Other than Double Shear . When a joint consists of two ...
Page 151
... Joints . Joints not indicated on the plans shall be so made and located as least to impair the strength of the completed structure . Where a joint is to be made , any excess water and laitance shall be removed from the surface after ...
... Joints . Joints not indicated on the plans shall be so made and located as least to impair the strength of the completed structure . Where a joint is to be made , any excess water and laitance shall be removed from the surface after ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood