... joists or beams shall be filled with loose incombustible materials placed in an incombustible support , or a metal collar connected to the chimney and fastened to the joists , beams or flooring to form an effective fire stop . All joists ...
... joists or beams shall be filled with loose incombustible materials placed in an incombustible support , or a metal collar connected to the chimney and fastened to the joists , beams or flooring to form an effective fire stop . All joists ...
Page 209
... joists . Sec . 3103. Steel joisted floors shall consist of steel joists as Steel specified in Section 2715. When used in Type I or Type II build- Joisted ings they shall have a reinforced concrete or gypsum slab not Floors less than two ...
... joists . Sec . 3103. Steel joisted floors shall consist of steel joists as Steel specified in Section 2715. When used in Type I or Type II build- Joisted ings they shall have a reinforced concrete or gypsum slab not Floors less than two ...
Page 211
... joists for Douglas fir and Southern pine using a 1200f grade , surfaced four sides to American Lumber Standard sizes and based on live load of 40 pounds per square foot uniformly dis- tributed . Joists of other grades , other woods and ...
... joists for Douglas fir and Southern pine using a 1200f grade , surfaced four sides to American Lumber Standard sizes and based on live load of 40 pounds per square foot uniformly dis- tributed . Joists of other grades , other woods and ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood