The thickness of plaster protection shall be measured from the face of the plaster to the plane of the back surface of the metal or wire lath where such lath is used and shall include two - thirds of the thickness of the gypsum plaster ...
The thickness of plaster protection shall be measured from the face of the plaster to the plane of the back surface of the metal or wire lath where such lath is used and shall include two - thirds of the thickness of the gypsum plaster ...
Page 253
Incombustible studding with metal or wire lath . 34 - in . plaster on each side Incombustible studding with metal or wire lath . 1 - in . plaster on each side Wood studs with metal or wire lath . Fire - stopped .
Incombustible studding with metal or wire lath . 34 - in . plaster on each side Incombustible studding with metal or wire lath . 1 - in . plaster on each side Wood studs with metal or wire lath . Fire - stopped .
Page 268
PART X CHAPTER 47 - LATHING AND PLASTERING General Sec . 4701. Lathing and plastering shall be done in the manner and with the materials specified in this Chapter , and when required for fire protection shall also comply with the ...
PART X CHAPTER 47 - LATHING AND PLASTERING General Sec . 4701. Lathing and plastering shall be done in the manner and with the materials specified in this Chapter , and when required for fire protection shall also comply with the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone