Page 253
... lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Reinforcement not less than 0.2 % in each direction Unplastered Plastered each side or 6 4 * 3 * 2 * 6 * 5 * 4 * 3 * 5 * 4 * 4 * 3 * 10 * 8 * 2 * 2 ...
... lath Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Reinforcement not less than 0.2 % in each direction Unplastered Plastered each side or 6 4 * 3 * 2 * 6 * 5 * 4 * 3 * 5 * 4 * 4 * 3 * 10 * 8 * 2 * 2 ...
Page 268
... Lath . Wood lath shall conform to the require- ments of Section 13 ( b ) of A.S.A. " Standard Specifications for Gypsum Plastering Including Requirements for Lathing and Furring , " ( A42 , 1-1938 ) . ( g ) Fiber Insulation . Fiber ...
... Lath . Wood lath shall conform to the require- ments of Section 13 ( b ) of A.S.A. " Standard Specifications for Gypsum Plastering Including Requirements for Lathing and Furring , " ( A42 , 1-1938 ) . ( g ) Fiber Insulation . Fiber ...
Page 271
... lath , and shall be not less than two- coat work when applied over other plaster bases allowed in this Chapter . Lime or cement plaster shall not be applied directly to fiber insulation lath or gypsum lath . In no case shall a brush ...
... lath , and shall be not less than two- coat work when applied over other plaster bases allowed in this Chapter . Lime or cement plaster shall not be applied directly to fiber insulation lath or gypsum lath . In no case shall a brush ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood