... less than one - hour fire - resistive construction . When the space under a Division 4 occupancy is used for any purpose , it shall be separated from all parts of such Divi- sion 4 occupancy , including exits , by walls , floors and ...
... less than one - hour fire - resistive construction . When the space under a Division 4 occupancy is used for any purpose , it shall be separated from all parts of such Divi- sion 4 occupancy , including exits , by walls , floors and ...
Page 105
... less than five - eighths inch ( % " ) thick . Approved fiber board not less than seven - sixteenths inch ( 7/16 ′′ ) thick . Approved gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick . Approved plywood not less than five ...
... less than five - eighths inch ( % " ) thick . Approved fiber board not less than seven - sixteenths inch ( 7/16 ′′ ) thick . Approved gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick . Approved plywood not less than five ...
Page 254
... less than four inches ( 4 " ) in thickness with a top covering of not less than two inches ( 2 " ) of solid masonry , or shall consist of steel joists protected with fire - resistive materials of the kind and thickness shown in Table No ...
... less than four inches ( 4 " ) in thickness with a top covering of not less than two inches ( 2 " ) of solid masonry , or shall consist of steel joists protected with fire - resistive materials of the kind and thickness shown in Table No ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood