Page 101
... limited . Sec . 2103. The floor area of a Type IV building shall be Area limited as specified under Occupancy in Part III and Location Allowable in Part IV . Sec . 2104. Footings shall be of solid masonry as specified in Foundations ...
... limited . Sec . 2103. The floor area of a Type IV building shall be Area limited as specified under Occupancy in Part III and Location Allowable in Part IV . Sec . 2104. Footings shall be of solid masonry as specified in Foundations ...
Page 203
... limited to not more than 30 times the average diameter . The diameter of piles cast in place shall be not less than eight inches ( 8 ′′ ) at the point and shall have an average diameter of not less than eleven inches ( 11 " ) . Precast ...
... limited to not more than 30 times the average diameter . The diameter of piles cast in place shall be not less than eight inches ( 8 ′′ ) at the point and shall have an average diameter of not less than eleven inches ( 11 " ) . Precast ...
Page 258
... limited to a maximum size of sixty square feet ( 60 sq . ft . ) with a six - foot ( 6 ' ) maximum width and a ten - foot ( 10 ′ ) maximum height for double hung and counterbalanced windows and to a maximum size of seventy square feet ...
... limited to a maximum size of sixty square feet ( 60 sq . ft . ) with a six - foot ( 6 ' ) maximum width and a ten - foot ( 10 ′ ) maximum height for double hung and counterbalanced windows and to a maximum size of seventy square feet ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood