... materials offered Materials as an alternate for the types of construction or materials re- and Types quired by this Code , but such alternate types of construction of Con- or materials to be given consideration shall be offered for ap ...
... materials offered Materials as an alternate for the types of construction or materials re- and Types quired by this Code , but such alternate types of construction of Con- or materials to be given consideration shall be offered for ap ...
Page 148
... materials for ready mixed concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready Mixed Concrete , " ( 94-42T ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent ...
... materials for ready mixed concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready Mixed Concrete , " ( 94-42T ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent ...
Page 247
... materials , systems , units and forms of Fire - Re- construction as regulated by this Code shall be classified as sistive " four - hour fire - resistive construction , " " three - hour fire - resistive Construc- construction , " " two ...
... materials , systems , units and forms of Fire - Re- construction as regulated by this Code shall be classified as sistive " four - hour fire - resistive construction , " " three - hour fire - resistive Construc- construction , " " two ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood