Page 58
... means of egress at least one of which shall lead directly to a street or court . These exits shall be not less than three feet six inches ( 3 ' - 6 " ) in width . All such exits shall be located as far apart as is practicable and all ...
... means of egress at least one of which shall lead directly to a street or court . These exits shall be not less than three feet six inches ( 3 ' - 6 " ) in width . All such exits shall be located as far apart as is practicable and all ...
Page 66
... means of egress shall have added to its required width one exit- width unit . 9. Rooms having required width of exits directly to the ex- terior need not be considered in determining the required width of corridors , halls or stairs ...
... means of egress shall have added to its required width one exit- width unit . 9. Rooms having required width of exits directly to the ex- terior need not be considered in determining the required width of corridors , halls or stairs ...
Page 220
... means of egress for the occupants of the building and access shall be provided thereto by means of a public room , public hall or passageway not less than thirty - six inches ( 36 " ) in clear width and in no case shall access thereto ...
... means of egress for the occupants of the building and access shall be provided thereto by means of a public room , public hall or passageway not less than thirty - six inches ( 36 " ) in clear width and in no case shall access thereto ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood