Page 58
... measured along the wall . ( d ) Balcony and Gallery Exits . For balconies or galleries having a seating capacity of over 50 , exits shall be provided from each side of each balcony or gallery , leading directly to a street or exit court ...
... measured along the wall . ( d ) Balcony and Gallery Exits . For balconies or galleries having a seating capacity of over 50 , exits shall be provided from each side of each balcony or gallery , leading directly to a street or exit court ...
Page 148
... Measurement of materials for ready mixed concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready ... measuring concrete materials shall be such that the proportions of all materials can be accurately controlled during ...
... Measurement of materials for ready mixed concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready ... measuring concrete materials shall be such that the proportions of all materials can be accurately controlled during ...
Page 251
... measured as specified for solid masonry walls in this paragraph . Where hollow units are laid with cells vertical ( end construction ) and the hollow spaces are not thus filled , the re- quired effective thickness of walls shall be measured ...
... measured as specified for solid masonry walls in this paragraph . Where hollow units are laid with cells vertical ( end construction ) and the hollow spaces are not thus filled , the re- quired effective thickness of walls shall be measured ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood