Page 84
... REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones ... meet the requirements of this Section . ( b ) Limitation of Types of Construction . 1. Type III . Build- ings or ...
... REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones ... meet the requirements of this Section . ( b ) Limitation of Types of Construction . 1. Type III . Build- ings or ...
Page 85
... meet the requirements of this Section . ( b ) Limitation of Types of Construction . 1. Type IV . Build- ings or structures of Type IV construction having an area greater than seventy - five hundred square feet ( 7,500 sq . ft . ) shall ...
... meet the requirements of this Section . ( b ) Limitation of Types of Construction . 1. Type IV . Build- ings or structures of Type IV construction having an area greater than seventy - five hundred square feet ( 7,500 sq . ft . ) shall ...
Page 247
... meet the respective requirements for such rating as specified in the A.S.T.M. " Stand- ard Specifications for Fire Tests of Building Construction and Materials , " ( C19-41 ) . Any materials , systems , units or forms of construction which ...
... meet the respective requirements for such rating as specified in the A.S.T.M. " Stand- ard Specifications for Fire Tests of Building Construction and Materials , " ( C19-41 ) . Any materials , systems , units or forms of construction which ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood