... one - hour fire - resistive doors and such doors shall be kept normally closed . The total width of all openings in any " Special Occupancy Separation " wall in any one story shall not exceed 25 per cent of the length of the wall in ...
... one - hour fire - resistive doors and such doors shall be kept normally closed . The total width of all openings in any " Special Occupancy Separation " wall in any one story shall not exceed 25 per cent of the length of the wall in ...
Page 63
... one - hour fire - resistive construction . When the space under a Division 4 occupancy is used for any purpose , it shall be separated from all parts of such Divi- sion 4 occupancy , including exits , by walls , floors and ceilings of ...
... one - hour fire - resistive construction . When the space under a Division 4 occupancy is used for any purpose , it shall be separated from all parts of such Divi- sion 4 occupancy , including exits , by walls , floors and ceilings of ...
Page 254
... hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists protected with fire - resistive ma ...
... hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists protected with fire - resistive ma ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood