Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 52
Page 51
... 1. An " Absolute Occupancy Separation " shall have no open- ings therein and shall be of not less than four - hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less than three - hour fire - resistive ...
... 1. An " Absolute Occupancy Separation " shall have no open- ings therein and shall be of not less than four - hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less than three - hour fire - resistive ...
Page 63
... one - hour fire - resistive construction . The Building Inspector may cause all Division 4. structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies shall Location on front ...
... one - hour fire - resistive construction . The Building Inspector may cause all Division 4. structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies shall Location on front ...
Page 254
Pacific Coast Building Officials Conference. Fire - Resistive Floor , Roof and Ceiling Construction ( Cont'd . ) Four - hour ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists protected with fire ...
Pacific Coast Building Officials Conference. Fire - Resistive Floor , Roof and Ceiling Construction ( Cont'd . ) Four - hour ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists protected with fire ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood