Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 42
Page 35
... permit therefor from the Build- ing Inspector . Any person desiring a building permit as required by this Code shall file with the Building Inspector an application there- for in writing on a blank form to be furnished for that purpose ...
... permit therefor from the Build- ing Inspector . Any person desiring a building permit as required by this Code shall file with the Building Inspector an application there- for in writing on a blank form to be furnished for that purpose ...
Page 36
... permit for the specified construction upon receipt of the required permit fee . When the Building Inspector issues the permit , he shall en- dorse in writing or stamp on both sets of plans and specifications ... Permit Building Permits.
... permit for the specified construction upon receipt of the required permit fee . When the Building Inspector issues the permit , he shall en- dorse in writing or stamp on both sets of plans and specifications ... Permit Building Permits.
Page 37
... permit , the fees above specified shall be doubled , but the payment of such double fee shall not relieve any ... permit shall be commenced until the permit holder or his agent shall have posted the building permit card in a conspicuous ...
... permit , the fees above specified shall be doubled , but the payment of such double fee shall not relieve any ... permit shall be commenced until the permit holder or his agent shall have posted the building permit card in a conspicuous ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood