Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 71
Page 36
... permit for the specified construction upon receipt of the required permit fee . When the Building Inspector issues the permit , he shall en- dorse in writing or stamp on both sets of plans and specifications " APPROVED . " One such ...
... permit for the specified construction upon receipt of the required permit fee . When the Building Inspector issues the permit , he shall en- dorse in writing or stamp on both sets of plans and specifications " APPROVED . " One such ...
Page 54
... Permitted 2 2 2 2 5 6 5 3 Not III Permitted 1 1 Not IV Permitted 1 11 33 3 1112 22 3 3 V Not Permitted 1 1 2 2 2 3 Allowable Area Increases Sec . 506. ( a ) General . The increases of floor areas permit- ted in this Section may be ...
... Permitted 2 2 2 2 5 6 5 3 Not III Permitted 1 1 Not IV Permitted 1 11 33 3 1112 22 3 3 V Not Permitted 1 1 2 2 2 3 Allowable Area Increases Sec . 506. ( a ) General . The increases of floor areas permit- ted in this Section may be ...
Page 106
... permitted in this Code . Sec . 2209. Fire - protection of structural framework shall not be required except as provided under Occupancy in Part III . Sec . 2210. Floors may be of any type of construction per- mitted in this Code . Sec ...
... permitted in this Code . Sec . 2209. Fire - protection of structural framework shall not be required except as provided under Occupancy in Part III . Sec . 2210. Floors may be of any type of construction per- mitted in this Code . Sec ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood