Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 28
Page 40
... persons engaged in the doing or causing such work to be done , and any such persons shall forthwith stop such work until authorized by the Building In- spector to recommence and proceed with the work . Whenever any building or portion ...
... persons engaged in the doing or causing such work to be done , and any such persons shall forthwith stop such work until authorized by the Building In- spector to recommence and proceed with the work . Whenever any building or portion ...
Page 45
... person living alone or a group of two F or more persons living together , whether related to each other by birth or not . FIRE RESISTANCE or FIRE - RESISTIVE CONSTRUC- TION is construction to resist the spread of fire , details of which ...
... person living alone or a group of two F or more persons living together , whether related to each other by birth or not . FIRE RESISTANCE or FIRE - RESISTIVE CONSTRUC- TION is construction to resist the spread of fire , details of which ...
Page 56
... persons or major fraction thereof to and including 1000 persons , with an additional one foot ( 1 ' ) per 100 persons for each additional 100 persons or major fraction there- of to and including 2000 persons and an additional six inches ...
... persons or major fraction thereof to and including 1000 persons , with an additional one foot ( 1 ' ) per 100 persons for each additional 100 persons or major fraction there- of to and including 2000 persons and an additional six inches ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood