Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 43
Page 227
Such chimneys shall be built up from the floor level on which they are used and in no case shall a stove pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a building they shall be supported by ...
Such chimneys shall be built up from the floor level on which they are used and in no case shall a stove pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a building they shall be supported by ...
Page 232
Ninety degree bends in round pipe shall be made by not less than four piece elbows . Sixty degree bends shall be made by means of not less than three piece elbows . All warm air pipes and fittings , cold air or recirculating pipes ...
Ninety degree bends in round pipe shall be made by not less than four piece elbows . Sixty degree bends shall be made by means of not less than three piece elbows . All warm air pipes and fittings , cold air or recirculating pipes ...
Page 237
Basement pipe inlets shall be installed in the first Basement floor of every store , warehouse or factory where there are Pipe cellars or basements under same , except where in such cellars Inlets or basements there is installed an ...
Basement pipe inlets shall be installed in the first Basement floor of every store , warehouse or factory where there are Pipe cellars or basements under same , except where in such cellars Inlets or basements there is installed an ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone