Page 227
... pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a build- ing they shall ... pipe intakes shall be set not less than eighteen inches ( 18 " ) below sheet metal ceilings , wood lath and plaster ...
... pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a build- ing they shall ... pipe intakes shall be set not less than eighteen inches ( 18 " ) below sheet metal ceilings , wood lath and plaster ...
Page 232
... pipes . All riser pipes shall be braced or held in place by means of metal strips securely fastened to the pipe and shall in no case be held in place by nailing diagonally through the corners of such pipe . No joint shall depend wholly ...
... pipes . All riser pipes shall be braced or held in place by means of metal strips securely fastened to the pipe and shall in no case be held in place by nailing diagonally through the corners of such pipe . No joint shall depend wholly ...
Page 237
... pipe inlets shall be installed in the first Basement floor of every store , warehouse or factory where there are Pipe cellars or basements under same , except where in such cellars Inlets or basements there is installed an automatic ...
... pipe inlets shall be installed in the first Basement floor of every store , warehouse or factory where there are Pipe cellars or basements under same , except where in such cellars Inlets or basements there is installed an automatic ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood