Page 45
... precast and used as a trim , veneer or facing on or in buildings or structures . CELLAR is that portion of a building between floor and ceil- ing which is wholly or partly below grade ( as defined in this Section ) and so located that ...
... precast and used as a trim , veneer or facing on or in buildings or structures . CELLAR is that portion of a building between floor and ceil- ing which is wholly or partly below grade ( as defined in this Section ) and so located that ...
Page 118
... precast or poured - in - place slabs or tiles of reinforced gyp- sum shall be based on the assumptions , limitations , and methods of stress determination specified for reinforced concrete in Chapter 26 . ( d ) Suspension Systems ...
... precast or poured - in - place slabs or tiles of reinforced gyp- sum shall be based on the assumptions , limitations , and methods of stress determination specified for reinforced concrete in Chapter 26 . ( d ) Suspension Systems ...
Page 203
... Precast concrete piles shall be sufficiently cured to attain the ultimate strength upon which their use is based , before driving . Such piles shall be reinforced and so handled as not to be fractured in any manner which will affect ...
... Precast concrete piles shall be sufficiently cured to attain the ultimate strength upon which their use is based , before driving . Such piles shall be reinforced and so handled as not to be fractured in any manner which will affect ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood