... proscenium curtain shall be supported on the proscenium wall by means of steel brackets of suitable size safely to carry the weight , or shall be mounted on structural steel beams . Blocks shall be installed so that the head - block is ...
... proscenium curtain shall be supported on the proscenium wall by means of steel brackets of suitable size safely to carry the weight , or shall be mounted on structural steel beams . Blocks shall be installed so that the head - block is ...
Page 246
... proscenium opening . For hydraulic or manual operation the endless line shall be marked plainly with an arrow pointing the direction for closing . For manual operation the operating hand line shall be not less than three - fourths inch ...
... proscenium opening . For hydraulic or manual operation the endless line shall be marked plainly with an arrow pointing the direction for closing . For manual operation the operating hand line shall be not less than three - fourths inch ...
Page 292
... proscenium curtain after test . Of Registered Inspector 4105 204 Over proscenium ARC WELDS ( see WELDING ) AREA CONSTRUCTION ) Definition of opening . APPROVED - Definition of ARCHES In fireplace construction In solid masonry ARCHITECT ...
... proscenium curtain after test . Of Registered Inspector 4105 204 Over proscenium ARC WELDS ( see WELDING ) AREA CONSTRUCTION ) Definition of opening . APPROVED - Definition of ARCHES In fireplace construction In solid masonry ARCHITECT ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood