Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 57
Page 95
ported at proper intervals from a structural beam or girder which is fire - protected on all sides . For openings in masonry bearing walls not exceeding four feet ( 4 ' ) in width , an angle or similar member supported by masonry and ...
ported at proper intervals from a structural beam or girder which is fire - protected on all sides . For openings in masonry bearing walls not exceeding four feet ( 4 ' ) in width , an angle or similar member supported by masonry and ...
Page 231
titions shall be protected with a metal or asbestos shield . The distance from any such range to any wood ceiling or other combustible material above shall not be less than twelve inches ( 12 " ) and if less than three feet ( 3 ' ) the ...
titions shall be protected with a metal or asbestos shield . The distance from any such range to any wood ceiling or other combustible material above shall not be less than twelve inches ( 12 " ) and if less than three feet ( 3 ' ) the ...
Page 254
... consist of steel joists protected with fire - resistive materials of the kind and thickness shown in Table No. ... all reinforcing , tie rods and supporting structural members in such floors shall be protected with not less than ...
... consist of steel joists protected with fire - resistive materials of the kind and thickness shown in Table No. ... all reinforcing , tie rods and supporting structural members in such floors shall be protected with not less than ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone