Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 7
Page 40
... representative may enter any building or premises for the purpose of inspection or to prevent violation of this Code , upon presentation of the proper credentials . Whenever any building work is being done contrary to the provisions of ...
... representative may enter any building or premises for the purpose of inspection or to prevent violation of this Code , upon presentation of the proper credentials . Whenever any building work is being done contrary to the provisions of ...
Page 146
... representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests shall be made by com- petent persons approved by the Building Inspector and copies of the results shall be kept ...
... representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests shall be made by com- petent persons approved by the Building Inspector and copies of the results shall be kept ...
Page 234
... representative of the Fire Department whenever deemed necessary and ordered by the Building Inspector . The tests shall be applied at the top and bottom connections of such standpipes and the owner or contractor shall be responsible for ...
... representative of the Fire Department whenever deemed necessary and ordered by the Building Inspector . The tests shall be applied at the top and bottom connections of such standpipes and the owner or contractor shall be responsible for ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood